NON WALKABLE ROOFS - NON INSULATED

Non walkable roofs - Non insulated,

1 Support: Concrete - Wood - Metal

2 Priming coat: Primertec AD (do not use on wood)

3 Adhesive, connecting and sectoring element: Plura Thermo AD V 2,5 mm

4 Reinforced corner: with membrane BPP P 4 mm > di 250 mm

5 Waterproofing element: Pratiko P+V

6 Double reinforced corner: Pratiko P+V

7 Finishing element: Metal flashing expansion joint with mechanical fixings and seal with Pratiko Mastic